Category: Flicker

Active Harmonic Filters – Buyer’s Guide

Active Harmonic Filters are growing in popularity as a method to mitigate power quality issues. There are several factors to consider when specifying an active harmonic filter. Typical applications for active filters are compensation of variable frequency drives and data-centers to reduce the load on UPS systems or compensating the effects of renewable energy sources on the grid.Active Harmonic Filter

What is an Active Harmonic Filter and what is its Application.

The general definition to describe this application is an analog or digital device that measures the power quality on the grid side. It then injects current to compensate any unwanted deviations from the standard 50 or 60 Hz supply. Deviations can be mitigated in full or partially.

What Factors to Consider when Specifying an Active Harmonic Filter

Sensor or sensorless control

There are suppliers that provide sensorless control eliminating the need for current transformers. This solution reduce the installation cost. Sensorless is not used in all applications so make sure to check the application with the supplier. Sensorless control or voltage control as it is sometimes defined compensates the total THD. It is not possible to select a single source such as a single VFD. On the plus-side it is possible to protect a sensitive subgrid from a noisy primary grid.

Losses

Depending on design, the filter has higher or lower losses. Check the losses as this will reduce the Life Cycle Cost on your investment. Some active filters have up to 1%-point lower losses, which depending on your user profile, means a potential for  considerable financial savings if calculated LCC over 5 years.

Harmonic Compensation Capacity

Harmonics are normally seen in the odd. Common capacity for active filters is 25th or 50th harmonic. Sometimes there is a claim of being able to mitigate the 51st harmonic, which has little value as harmonic order of 51 and above are normally not important.

Harmonics above the 50th are more difficult to measure as there are few PQ-meters that can handle such orders. There are however quite common sources such as Active Front End Drives that cause switching ripple above 3kHz, above the 60th harmonic (or above the 50th in 60 Hz systems).

There are a few Active Harmonic Filters capable of compensating such frequencies. Choose a filter according to the needs specified by your measurements.

A filter’s capacity to compensate a certain harmonic order is only part of the story. Another important factor is de-rating, discussed below.

Response time

Some power quality phenomena occur extremely fast requiring the mitigation to be even faster.  If your process is affected by fast flicker or transients, take special care to evaluate the response capacity of the filter. Flicker is a specific phenomena that normally requires special software to compensate flicker in a controlled environment.

Interharmonics

Interharmonics is commonly caused by syncronisation issues. If  your installation includes such interharmonic sources, the type of active filter changes and the vendor has to be consulted. This is a common issue on some types of older wind turbines.

EMC

In Europe there are strict guidelines regarding EMC. If you want to be sure that the active filter does not interfere, the filter must be fitted with a properly tuned EMC-filter.

De-rating

An Active Harmonic Filter’s rating is normally defined at nominal load, meaning at 50/60Hz. As the filter works further up the harmonics its capacity compared to nominal starts to de-rate. The de-rating curve is documented by all serious suppliers and should be available if you ask them.

A de-rating of 50%, at say the 13th harmonic, means that a 100A filter only has the capacity to compensate 50A at the 13th.  Naturally if you have harmonics of higher order it becomes more important to check the de-rating.

De-rating is a matter of how robustly the filter is designed. Some suppliers offer zero de-rating up to the 7th before capacity starts to fall.

Physical Footprint – How Much Cabinet Space is Required?

Most active filter suppliers offer several alternatives regarding installation. Wall mount, Cabinet and IP00 modules to install in cabinets. Efficient use of cabinet space translates to lower system cost. Some filters have a modular design and can be enhanced with further capacity without adding to the footprint.

Modularity

As mentioned, a modular design of your Active Harmonic Filter enables you to adapt the filter to potential changes in your future power compensation needs. The modular design means that you can easily add to the filter’s capacity within the existing cabinet, saving both cost and space.

Commissioning Software

Does the filter have built in commissioning software?  Commissioning and service of Active Filters can be quite time consuming. Ask for a review of the support software included in the machine. Some suppliers have an extra charge for the necessary software. Minimum required functionality should be that the system performs a self-check of Voltage and CT phase order, CT polarity check, self-diagnosis, and self-calibration. Such features will quickly find installation errors before they can cause problems and will also shorten the needed commissioning time.

If the filter does not have this type of support software the commissioning becomes much more complex and might even require external support adding to the system cost.

HMI

There are different HMI setups. Some have a very simple front HMI while others include graphs showing the current and voltage waveforms and many further functions. A great added value is to have at least a web-based interface allowing in-depth monitoring and control functionality. Then no extra PQ-meter is necessary.

Smart Grid Functionality

Active filters have a built in rudimentary power and power quality meter to calculate the required compensation. Some filter manufacturers make use of this fact and enable the user to connect all filters on site and company wide through a web based architecture.  An operator can then have an overview of the status of all connected cabinets and log them. This enables the possibility to log events that could or should have caused production disturbances, status monitoring of individual filters as well as remote control capability.  Email and text alerts to dedicated service personnel from the filter reduce response time dramatically.

IP/NEMA Class and Water Cooling

Water-cooled Active Filters enable very good cooling of the IGBTs, the most critical component in the Active Filter. Water-cooling reduces overheating immensely, which increases availability in the same way as for Variable Frequency Drives. The power density of the installation is also improved.

Voltage

Active Harmonic Filters are offered in a range of voltages.  Most common ranges are 380–415V, up to 480 V. Higher voltages up to 600 and 690V are also available without step-up transformer, reducing foot print. Some suppliers have the capacity to supply MV ratings as well, normally using a step-up transformer. The active filter can then act as STATCOM.

Battery add-on

In recent years several suppliers are offering battery connectivity to create a battery energy storage system for FCR and peak shaving. The active filters on-load capabilities are perfect for grid connectivity applications.

Sensorless Voltage Control

Recently a new type of sensorless solution make it much easier to install as no CTs are required which is standard for active harmonic filters. This method can not control specific frequencies but can be used to even mitigate noise from the grid.

Resonance Damping

Some filters offer resonance damping making them ideal in highly complex situations.

 

 

 

 

Applications of Active Filter Technology

English: The , also known as the Green Mountai...

Wind Energy (Photo credit: Wikipedia)

Active Harmonic Filter Technology have many potential applications where its use can offer plenty of benefits. Active Filters have been proven to provide lowered disturbances, lower carbon dioxide emissions through improved energy efficiency, lower current consumption and increased production stability to name a few. Just as other technology has evolved, so have various production technologies. Today’s semiconductor loads require far more sophisticated solutions than was necessary in the past – a need met by modern Active Filtering technology.

Some of the most common applications for Active Harmonic Filters are:

Variable Speed Drives

The most common application for Active Filters is the compensation of harmonics generated by variable speed drives, often referred to as VFDs or Frequency Converters. Drive systems have the benefits of lower losses and increased production flexibility at the cost of higher harmonics emissions. Harmonics emissions make passive compensation unsuitable. Active harmonic filtering, especially with a modular approach, allows successive installation and mitigation of selected harmonics.

Welding Plants

Electrical welding systems place uneven demands with extremely high peaks in current demand during short periods. The resulting highly fluctuating voltage levels cause flicker. Flicker emissions can cause disturbances with other electrical consumers such as neighboring industries or residential areas and can cause reliability issues with nearby equipment. Active Filters can mitigate Flicker.

Furnaces

Furnaces and casting processes are known to give rise to both flicker and harmonics. This is largely due to being some of the most energy intensive production processes today. Active Filtering technology is ideal to combat both of these issues to increase production stability and reduce effects on the grid.

Wind and Solar Power Systems

A major problem inherent in many renewable energy sources today is the inconstant load delivered to the grid. Both wind and solar energy is delivered as wind and sun is available, causing surges of energy that the existing grid is usually not built for. The remote location of these energy plants also means that grid connections are suboptimal.

Wind power systems cause flicker, harmonics or interharmonics as well as other problems. Solar power plants cause harmonics and interharmonics. In some cases, especially in weaker networks, resonances may be excited by the harmonic output of the solar inverters. Modern Active Filtering technology is very effective in combatting these problems; reducing the stress placed on the grid and making these renewable energy sources more effective and widely viable.

Lighting

Light systems can cause harmonics that heat neutral conductors and disturb nearby equipment. This can mean production disturbances and unnecessary maintenance costs. Modern energy saving lamps may be more likely to cause disturbances depending on type. Active Filters are well suited to combat these problems.

UPS Systems

UPS or Uniterruptible Power Suplies can save lives as well as data and financial loss. A UPS system connected to a network polluted with harmonics can malfunction and has a shortened life span. Connecting an Active Filter to secure uninterrupted power supply will ensure production uptime.

STATCOM Case Study

STATCOM AHF Reduces Flicker

Due to an increased usage of the local grid, a stricter limit of flicker emission became a necessity. One of the largest steel wire producers in Europe managed the problem by installing a STATCOM solution and lowering their flicker emissions.

Background

Flicker before statcom compensation

Flicker Before STATCOM Compensation

The processing plant is the largest steel wire producer in Europe, part of a German industry group founded in 1856. The company produces steel reinforcement mesh grids. The production line is made up of various welding equipment, including spot welders from Schlatter AG. As is the case with all powerful spot welders, the abrupt current consumption causes voltage variations, which in turn produces flicker.

Challenge

Due to expansion of the area and increased amount of renewable energy sources, it became necessary to lower flicker contribution. Early reference measurements showed flicker levels up to Pst 2 and Plt 1.4. A futher

Flicker after STATCOM compensation

Flicker after STATCOM compensation

complication the the case was caused by a lot of switching activity in the surrounding electrical grid. This contributed to higher background flicker and making measurements more difficult. Finally, depending on the production type currently running, the flicker will vary.

STATCOM by AHF – the Solution

The solution was offered in cooperation with Schlatter AG, who also delivered the welding lines.
A STATCOM solution consisting of 7 300/690W water cooled active harmonic filters was installed. The nominal installed power is 2.5 MVAr. The fully water cooled STATCOM follows the load dynamically. Neither changes in the production nor newly installed equipment leads to any need for adjustment of the compensation system. The AHF units were installed via a dedicated transformer and use their own medium voltage measurement point.

Delivered Results

The STATCOM solution reduced the flicker level to Plt 0.6. Reduced reactive power lowered current consumption 25-40%. Voltage dips on the 20 kV rail were lowered from around 500V to around 100V.